REDBOX RBC6040


    This listing is currently not for sale or available for charter


    Aircraft Summary


    General

    Manufacturer
    REDBOX
    Model
    RBC6040
    Condition
    New
    Description
    Cost-Effective, Compact and Dependable: RBC6000 series Frequency Converters provide the most cost-effective and flexible way of providing 400Hz and 60Hz all-weather ground power for helicopters, military jets, civil aircraft and workshop use. By using the most advanced electronic design, RBC6000 models offer a remarkably compact, quiet and robust converter. This means that personnel may work in close proximity to them without the tiring noise normally associated with 400Hz 60Hz converters. Simplicity in Operation: ‘Two button’ operation. An emergency stop is also fitted. Output and Aircraft Interlocks: All models may be ordered with an additional output (up to 600 Amps). This may be supplied to be used either concurrently with the 400Hz output or independently. Aircraft interlocks for both military and civil aircraft may also be ordered and a manual interlock override is standard. Applications: RBC6000 series machines are suitable for static installations within plant rooms, hangars and workshops. Besides supplying aircraft they may also be used for powering production lines, test and development laboratories and simulators. All-Weather 40, and 60 180KVA units are supplied as standard within an all weather cabinet. This is optional with all other units. High MTBF, Low MTTR: An oversized rectifier and robust IGBT based inverter offer high reliability, while modular construction and a simple lay-out means that access for maintenance and repair is very straight forward. • Military and Civil Models • Optional All Weather IP54 Training Cabinet • Aircraft Interlock with Manual Override • Low Acoustic Noise • Simple Operation • Comprehensive Analogue Output Display These units can be fitted with a Charge Management System that allows the user to charge their customers for the power used whilst an aircraft is connected to a RBC6000 frequency converter, RBC5000 transformer rectifier unit or and RBSC DC Power Supply. The system is an ideal platform for airport operators who want to pass on the cost of supplying ground power to aircraft on turnaround. Specification: INPUT: Mains Supply Voltage: 230/400VAC ±10% Single or Three Phase (other voltages available on request). Mains Supply Frequency: 50 or 60HZ ±5% (other frequencies available on request – 16-440Hz). Power Factor: 0.99Pf @ full load. Input Protection: MCB to BS EN 60898 Protections: DC over-voltage protection, mains low protection and input surge protection. Technology: Full wave controlled thyristor / diode bridge with IGBT power factor correction. OUTPUT: Voltage: 200/208 or 280/400/415VAC Three Phase, other voltages available on request. Voltage Regulation: Static ±1%, Dynamic ±6%. Output Wave Form: Sinusoidal Frequency: 50, 60 or 400HZ ±0.1% (other frequencies available on request – 16-850Hz) Distortion (THD): <3% into linear load. Load Power Factor: 0.3 lag to 0.3 lead. Crest Factor: 3:1 Overload (KVA): 120% continuous 121% for 2 minutes, 160% for 5 seconds without reduction in output voltage. Efficiency: 90-93% depending on system. Protections: Electronic overload / short circuit, over-temperature, inverter over/under-voltage and low DC shutdown. Technology: High Frequency, pulse width modulated IGBT with isolation transformer. 28V DC OUTPUT: 28.5V DC power supply optional, offering 600 Amps continuous and 2000 Amps peak. ENVIRONMENT & EQUIPMEMT: Ambient Temperature Range: -15 to 50 deg C Humidity: <90%, non-condensing Altitude: All specifications quoted at < 2000m above sea level GENERAL: Noise Level: <55dBA @ 1 metre. Maximum Relative Air Humidity: 90%, non-condensing. Maximum Altitude: 2000m Above sea level before de-rating. Max / Min Temperature: 0 - 40°C STANDARDS: BS EN 50091–1 (Safety) BS EN 50091–2 (EMC) BS EN 61000-3-4 (Harmonics) SIZE & WEIGHTS: Model Power Weight 6040 40KVA 460Kg 6060 60KVA 590Kg OPTIONS: OTHER INPUT VOLTAGE VARIOUS INPUT AND OUTPUT CABLE LENGTHS AND CONECTOR ADDITIONAL OUTPUT OF 28.5V DC CASE SIZE MM: Power Case Size mm Castor/Trailer 40KVA H1180 X W710 X D1100 mm Large, Heavy Duty Casters 60KVA H1630 X W810 X D1610 mm Large, Heavy Duty Casters Dimensions and weights can change without notice


    Click Here to find your Operating Cost


    Aircraft.com does not own the rights to the images displayed on this site. We do not have information regarding the original seller or source of these images unless explicitly stated.